LF10 Air Pressure Switches (25-175 PSI)

 

The LF10 pressure switches are used to regulate the tank pressure between two preset values on small (up to 175psi) electrically driven air compressors.

They are available with an unloader valve, which prevents compressors from starting under load, and an auto-off disconnect lever for manual cut off the compressor.

A four port manifold style is available which provides a means for easy mounting of valves and gauges.

 

MODEL Min ON (Cut-In) PSI Max Off

(Cut-Out) PSI

Differential

PSI

Factory Setting PSI Electrical Rating Pipe Fittings Contact Arrangement
120VAC 240VAC
LF10-1H1 25 100 20-30 50-80 20A 12A NPT 1/4 Male or Female NPT NC
LF10-1H2 35 150 30-40 85-115 20A 12A 1/4″ Male or Female NPT NC
LF10-1H3 50 175 35-55 110-150 20A 12A 1/4″ Male or Female NPT NC
LF10-4H1 25 100 20-30 50-80 20A 12A 1/4″ Female NPT (4 Port) NC
LF10-4H2 35 150 30-40 85-115 20A 12A 1/4″ Female NPT (4 Port) NC
LF10-4H3 50 175 35-55 110-150 20A 12A 1/4″ Female NPT (4 Port) NC

 

MODEL Min ON (Cut-In) PSI Max Off

(Cut-Out) PSI

Differential PSI Factory Setting PSI Electrical Rating Pipe Fittings Contact Arrangement
120VAC 240VAC
LF10A-1H1 25 100 20-30 50-80 26A 26A NPT 1/4 Male or Female NPT NC
LF10A-1H2 35 150 30-40 85-115 26A 26A 1/4″ Male or Female NPT NC
LF10A-1H3 50 175 35-55 110-150 26A 26A 1/4″ Male or Female NPT NC
LF10A-1H4 70 200 40-55 130-175 26A 26A 1/4″ Male or Female NPT NC
 

LF10A-4H1

25 100 20-30 50-80 26A 26A 1/4″ Female NPT (4 Port) NC
LF10A-4H2 35 150 30-40 85-115 26A 26A 1/4″ Female NPT (4 Port) NC
LF10A-4H3 50 175 35-55 110-150 26A 26A 1/4″ Female NPT (4 Port) NC
LF10A-4H4 70 200 40-55 130-175 26A 26A 1/4″ Female NPT (4 Port) NC

Approval: UL, CSA, TUV CE, CCC

G1/4 (BSP 1/4) Male or Female Pipe Fittings are available.

Conversion: 1Kgf/cm2 = 14.2PSI , 1bar = 14.5PSI